Reduced price! View larger

TIA/EIA-455-226

M00002650

New product

TIA/EIA-455-226 2002 Edition, May 1, 2002 FOTP-226 IEC 61746 Calibration of Optical Time-Domain Reflectometers (OTDR's)

More details

In stock

$62.78

-57%

$146.00

More info

Description / Abstract: This International Standard provides procedures for calibrating single-mode optical time domain reflectometers (OTDRs). It only covers OTDR measurement errors and uncertainties. It does not cover correction of the OTDR response.

In order for an OTDR to qualify as a candidate for complete calibration using this standard, it is to be equipped with the following minimum feature set:

a) a programmable index of refraction, or equivalent parameter;

b)the ability to present a display of a trace representation, with a logarithmic power scale and a linear distance scale;

c) two markers/cursors, which display the loss and distance between any two points on a trace display;

d) the ability to measure absolute distance (location) from the OTDR's zero-distance reference;

e)the ability to measure the displayed power level relative to a reference level (for example, the clipping level).